Sentyl
Day 00 · InoculateEarly warning · 03 Guard
Sentyl. Batch-failure warnings hours before they become losses.
Single-signal alarms miss the slow, combined signs of a batch going wrong. Sentyl compares every batch with the path the twin expects and raises one warning, with a likely cause, while there is still time to act.
Example One warning, illustrative.
Day 02 · LagCapabilities
What it does.
01
Twin residuals
Many signals compared with the twin’s expected path, not fixed limits.
02
Likely cause
Contamination, metabolic shift, foaming or sensor fault, ranked by likelihood.
03
Ranked actions
Suggested checks and corrections, for people to decide.
04
Deviation drafts
A first draft of the deviation note for QA review.
05
Sensor checks
Flags a drifting probe when the twin and the signal disagree.
06
Edge option
Runs beside the bioreactor on Jetson or IGX.
Day 04 · GrowthWarnings
A week of warnings, triaged.
- SEN-0311Day 8.5 · B-2611Metabolic shiftLactate rising against the twin’s expected path while glucose is highopen
- SEN-0314Day 4.2 · B-2614ContaminationOxygen uptake and pH diverge from twin; early contamination patternescalated
- SEN-0317Day 6.8 · B-2602FoamAntifoam demand climbing faster than the expected profileacted
- SEN-0320Day 2.1 · B-2615Sensor faultDissolved-oxygen probe drifting; twin estimate holds steadyclosed
- SEN-0322Day 10.4 · B-2609Metabolic shiftAmmonia trajectory above the twin band; viability at riskopen
- SEN-0325Day 7.3 · B-2611Sensor faultRaman glucose model and offline sample disagree by more than its bandacted
Example A week of Sentyl warnings across one suite. Batch IDs, days and findings are made up.
Day 06 · GrowthHow it works
One run, start to finish.
01Weeks 1–2
Learn
Normal behaviour from past batches and the twin.
02Weeks 3–6
Shadow
Warnings logged but not sent.
03Week 7
Tune
Your team sets limits and routing.
04Ongoing
Live
Warnings reach the right people.
05Per warning
Learn again
Every confirmed or dismissed warning trains the next.
Day 08 · ProductionSpecification
The details.
| Item | Detail |
|---|---|
| Signals | Process time series, PAT spectra, off-gas, assays; reactor video planned |
| Method | Multivariate residuals against the Kinetyx twin |
| Causes | Contamination, metabolic shift, foam, sensor fault; more per modality |
| Latency | Minutes from data to warning (design target) |
| Records | Warnings, triage and outcomes recorded |
| Runs on | RAPIDS, Holoscan, TensorRT; Metropolis for video (planned) |
Day 10 · ProductionIn the loop
Where it sits.
Every harvested batch and its assaysrecalibrate the Kinetyx twin
Sentyl uses the expected path from Kinetyx and the forecasts from Titera. Feedra stays inside the safe envelope that Sentyl watches.
Day 12 · Late productionQuestions
Straight answers.
Will it flood us with alarms?
It is tuned in shadow mode first, and every warning is triaged, so dismissed warnings make the next ones better.
Can it stop a batch?
No. It warns and drafts. People decide, under your procedures.
Does it need cameras?
No. Video for foam and turbidity is a planned option.
Day 14 · HarvestNext step
Bring one process. We will twin it.
Share the batch records and PAT data from one process you run today. We calibrate a twin of it, forecast your next runs before they finish, and show you where yield and quality are being left in the vessel.